Chapter 1 MAINTENANCE SERVICES
1-29 NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT REPORT SCHEDULING
FAULT REPORT SCHEDULING
General Description
This feature provides the system to register pre-determined date for periodic maintenance in advance and
notify the information on the day by the Multiline Terminal function key lamp or external alarm display
panel.
Service Conditions
(1) The maximum of eight pre-determined dates for periodic maintenance, for example, battery check,
are registered by CM43 Y=2 in advance.
(2) The notification for maintenance is indicated by the alarm lamp (MJ/MN) on the external alarm
panel, or the Multiline Terminal function key lamp. The Multiline Terminal function key steady
lights as MJ alarm, or flashes with 60 IPM as MN alarm. The MJ or MN alarm is selected by CMEA
Y=2 in advance.
(3) The number of Multiline Terminal which indicates the periodic maintenance is two in a system.
(4) The alarm indication can be cleared by CMEA Y=1 from CAT/PCPro.
CPU
PBX
Alarm Panel
MJ
MN
F
e
atur
e
F
ea
tu
re
4
5
6
GHI
GHI
J
KL
J
KL
7
8
9
P
QR
S
P
QRS
T
UV
T
UV
0
#
O
P
E
R
O
P
E
R
1
2
3
ABC
ABC
DEF
DEF
Multiline Terminal
Register the time of
periodic maintenance
Indicate the lamp
on the scheduled date
JULY/17/2009

Table of Contents

Other manuals for NEC Univerge SV8300

Related product manuals