Chapter 1 MAINTENANCE SERVICES
1-6 NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT MESSAGE
Programming Procedure
Fault Message
(1) To set the fault information storage from the PCPro by Command Operation
DESCRIPTION DATA
Enable the fault information storage feature. (1)
(2)
450
1: To store
Assign which kind of fault information is
stored into the fault information memory, and
which kind of alarm is indicated.
•
(1)
(2)
Y=2
See the following table.
See the following table.
NOTE: CMEA programming can be set by the PCPro.
START
CM08
CMEA
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
Fault Kind: Occurrence 0
3
External Alarm Kind
0: Fault Memory store/No output of
External Alarm
1: Fault Memory store/External Alarm is
MN alarm
2: Fault Memory store/External Alarm is
MJ alarm
3: No Fault Memory store/No External
Alarm output
001 System reset NOTE 1
012 CS/ZT fault occurred
016 It is a day periodic maintenance
017 Activation Code error occurred during the
License Activation (Center Activation)
021 ISDN D-channel link connection failure
022 CCIS link connection failure
025 Number of lockout stations was more than
predetermined number NOTE 2
026 DLC blade down
028 SMDR output buffer (SRAM) exceeded 80
%
[8300R3 software required]
029 SMDR output buffer (SRAM) overflow
[8300R3 software required]
02B CS/ZT fault occurred
02C LAN application fault occurred NOTE 3