EasyManua.ls Logo

NEC Univerge SV8300 - DESKCON Fault

NEC Univerge SV8300
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 TROUBLESHOOTING
2-56 NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
DESKCON Fault
DESKCON means SN716 DESKCON.
All keys on the DESKCON are
ineffective.
(1)
(2)
(3)
(4)
(5)
DESKCON Lock-out has been set via
the function key.
Wiring on Modular Box (Rosette)
DLC blade is properly mounted.
System Data Programming for the
console: CM05 Y=0, CM10 Y=00, CM60,
CM90 Y=00.
“RUN” Lamp on the CPU blade is flashing.
(1)
(2)
(3)
DESKCON
DLC blade
CPU blade
Speech Path Trouble
(No Connection/One-Way
Connection)
(1)
(2)
(3)
Headset or Handset on the console.
DESKCON
DLC blade
LCD does not display any infor-
mation.
(1) Adjust Display Contrast.
(1)
(2)
DESKCON
DLC blade
No Tone Ringer (1)
(2)
System Data Programming for the console
tone ringer: CM60 Y=16, 27
Adjust Ringer Volume on the console.
(1) DESKCON
START
CHECK
REPLACE
CHECK
CHECK
REPLACE
CHECK
REPLACE
END
APRIL/16/2010