Chapter 1 MAINTENANCE SERVICES
1-42 NWA-033627-001 Rev.4.0
95ch1001.fm
VoIP LOG COLLECTION
Programming Procedure
(1) To execute the fault logs/call logs collection, do the following programming.
DESCRIPTION DATA
Provide the call log collection with the
Vo I P D B .
NOTE: When changing this data for
VoIPDB accommodated in a remote
unit, execute the system data copy
by CMEC Y=8 to the remote unit.
(1)
(2)
Y=2XX (VOIP Port [2] + Unit No. [01-50])
90
0: To provide
1: Not provided
Provide the fault log collection with the
Vo I P D B .
(1)
(2)
Y=2XX (VOIP Port [2] + Unit No. [01-50])
91
0: Not provided
1: To provide
Assign Service Restriction Class C to the
required stations.
(1)
(2)
Y=07
X-XXXXXXXX: IP Station No.
00-15 : Service Restriction Class C
Allow call log collection in Service Restriction
Class C assigned by CM12 Y=07.
NOTE: When changing this data for
VoIPDB accommodated in a remote
unit, execute the system data copy
by CMEC Y=8 to the remote unit.
(1)
(2)
Y=194
00-15: Service Restriction Class C assigned
by CM12 Y=07
0 : Allow
1 : Restricted
Allow fault log collection in Service Restric-
tion Class C assigned by CM12 Y=07.
(1)
(2)
Y=195
00-15: Service Restriction Class C assigned
by CM12 Y=07
0 : Restricted
1 : Allow
START
CM0B
CM12
CM15
A