EasyManua.ls Logo

NEC Univerge SV8300 - Page 55

NEC Univerge SV8300
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 1 MAINTENANCE SERVICES
1-43 NWA-033627-001 Rev.4.0
95ch1001.fm
VoIP LOG COLLECTION
DESCRIPTION DATA
Specify the output destination for the fault
logs/call logs.
NOTE: Set the output port for fault logs/call
logs by CM40 Y=00.
(1)
(2)
Y=6
00: Output destination of logs
2 : RS port of CPU
3: Not output
Specify the collection method of fault logs/call
logs.
(1)
(2)
Y=6
02: Collection method of logs
0 : Not overwritten
1 : Overwrite
Specify whether fault logs are collected when
the IP Stations login to the system or the
VoIPDB is in online status.
(1)
(2)
Y=6
10: Fault log collection
0 : To collect
1 : Not collected
Specify the RS port to collect VoIP log.
(1)
(2)
Y=00
0: Unit01 Port1
1: Unit01 Port2
08 : VoIP log collection
NONE : No data
Specify the data length for the RS port.
NOTE: When using CPU RS-232C port for
PCPro, set the default.
(1)
(2)
Y=01
0: Unit01 Port1
1: Unit01 Port2
0: 7 bit
1: 8 bit
Specify the RS port to make effective the
parity check.
NOTE: When using CPU RS-232C port for
PCPro, set the default.
(1)
(2)
Y=02
0: Unit01 Port1
1: Unit01 Port2
0 : Effective
1 : Ineffective
Specify the kind of parity for the RS port.
NOTE: When using CPU RS-232C port for
PCPro, set the default.
(1)
(2)
Y=03
0: Unit01 Port1
1: Unit01 Port2
0 : Odd parity
1 : Even parity
A
CMEA
CM40
B
JULY/17/2009

Table of Contents

Other manuals for NEC Univerge SV8300