EasyManua.ls Logo

NEC Univerge SV8300 - Page 104

NEC Univerge SV8300
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 TROUBLESHOOTING
2-36 NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Remedial Action on Each LED Status
BLADE
NAME
LED STATUS
FAULT
CONTENT
REMEDIAL ACTION
CD-CCTA
(CCT)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
CCT blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-4LCA/
8LCA (LC)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
LC blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-8DLCA/
16DLCA
(DLC)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
DLC blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-4CSIB
(CSI)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
CSI blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-4CSIB-A
(CSI)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
CSI blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
APRIL/16/2010

Table of Contents

Other manuals for NEC Univerge SV8300

Related product manuals