Chapter 1 MAINTENANCE SERVICES
1-13 NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT MESSAGE
(2) To clear the MJ/MN alarm by external key
DESCRIPTION DATA
Assign a Unit and Slot number to the DLC
blade.
NOTE: When the PGD(2)-U10 ADP is
accommodated to the Remote Unit,
execute the system data copy by
CMEC Y=8 before executing the
blade reset.
(1)
(2)
Y=0
XX ZZ
XX: 01-50: Unit No.
ZZ : 01-18: Slot No.
10: DLC blade
Assign the station number connected to
PGD(2)-U10 ADP to its associated Physical
Port number.
(1)
(2)
Y=00
XX YY ZZ: Physical Port No.
XX: 01-50: Unit No.
YY: 01-18: Slot No.
ZZ : 01-32: Circuit No.
FX-FXXXXXXXX: Station No.
Assign the Kind of PGD(2)-U10 station.
(1)
(2)
Y=65
X-XXXXXXXX: Station No.
3: External relay/external key only
Specify the External Key group number.
(1)
(2)
Y=66
X-XXXXXXXX: Station No.
00-63 : External Key Group No.
Allow the accommodation of PGD(2)-U10
ADP.
(1)
(2)
Y=63
X-XXXXXXXX: Station No.
0 : To accommodate
1 : Not accommodated
NOTE1: Set this data only for a Base Port of DLC blade.
NOTE2: Whether the following equipments can be accommodated to the same DLC blade or not
are depended on this data.
- When the second data is set to “0”
Accommodatable : DT300/D
term
85/D
term
70/PGD(2)-U10 ADP
Unaccommodatable: D
term
75/DESKCON
- When the second data is set to “1”
Accommodatable : DT300/D
term
85/D
term
75/DESKCON
Unaccommodatable: D
term
70/PGD(2)-U10 ADP
START
CM05
BLADE RESET
CM10
CM12
CM13
BLADE RESET
A
APRIL/16/2010

Table of Contents

Other manuals for NEC Univerge SV8300

Related product manuals