Chapter 1 MAINTENANCE SERVICES
1-17 NWA-033627-001 Rev.4.0
95ch1001.fm
STATION LINE STATUS DISPLAY
Analog Line/Digital Line
00: LC (Single Line Tel.)
10: DLC (Digital Multiline Terminal)
20: IP Station
Hardware Test
See “Status of Single Line Telephone/Multiline Terminal” below.
Status of Single Line Telephone/Multiline Terminal
NOTE: When using the single line telephone, “Terminal is not connected” or “Terminal is connected”
cannot be displayed.
Software Test
01 - FF: See “Station Status Information” Page 1-22. (This data is same as the status code
of CMF5.)
INDICATION
STATUS OF
SINGLE LINE TEL.
STATUS OF
DIGITAL MULTILINE
TERMINAL
STATUS OF
IP STATION
00 Normal operation of
blade NOTE
Terminal is not connected
or Tip wire is grounded
Terminal is not connected
01 Blade is not mounted/
initialized NOTE
Terminal is connected Terminal is connected
02 Short circuit is made on
the line
03 Ring wire is grounded
04 DLC blade is not mounted
05 Terminal failure
06 DLC blade down
07
08 Line failure detected