Chapter 2 TROUBLESHOOTING
2-18 NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Remedial Action on Each Fault Kind
FAULT
KIND
NUMBER
FAULT
CONTENT
FAULT INFORMATION REMEDIAL ACTION
012 CS/ZT fault Fault Kind Details: SYS-ID download
failure
When input the SYS-ID
from PCPro, check if the
number is correct.
Check the CS/ZT is CS/
ZT without SYS-ID.
Make the CS/ZT busy or
idle condition by CME5
Y=3.
Turn OFF and ON the
CS/ZT power switch.
Fault Kind Details: CS/ZT make busy
failure
Make the CS/ZT busy or idle
condition by CME5 Y=3.
Fault Kind Details: CS/ZT data load
failure
Make the CS/ZT busy or
idle condition by CME5
Y=3.
Turn OFF and ON the
CS/ZT power switch.
Fault Kind Details: B channel make
busy failure
Fault Kind Details: CS/ZT operation
parameter change
failure
Fault Kind Details: LCCH sending
position failure
Fault Kind Details: Carrier selection
failure
[North America/Latin America
Only]
No specific action is required
Continued on next page