Chapter 2 TROUBLESHOOTING
2-23 NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Remedial Action on Each Fault Kind
FAULT
KIND
NUMBER
FAULT
CONTENT
FAULT INFORMATION REMEDIAL ACTION
029 SMDR output
buffer over-
flow
Fault Kind Details: RS-232C port Collect the charge informa-
tion from the SMDR.
Fault Kind Details: LAN port
Fault Kind Details: To PMS
Fault Kind Details: To Center office for
Centralized
Billing-CCIS
02B CS/ZT fault
occurred
Fault Kind Details: Fault notice from
CS/ZT
No specific action is required.
Fault Kind Details: CS/ZT reset failure Make the CS/ZT busy or
idle condition by CME5
Y=3.
Turn OFF and ON the
CS/ZT power switch.
Fault Kind Details: CS/ZT condition
read failure
Fault Kind Details: CS/ZT condition
unmatched
No specific action is required.
Fault Kind Details: B channel condi-
tion unmatched
No specific action is required.
Fault Kind Details: SYS-ID upload
failure
Check the CS/ZT with
SYS-ID is correct by
CMAE Y=00>09.
Make the CS/ZT busy or
idle condition by CME5
Y=3.
Turn OFF and ON the
CS/ZT power switch.
Continued on next page