ANPR LUMO | installation guide
You can reset the suppression of identical readings with the setting in Reset After (s) to retransmit a LP after some
time. If Reset After (s) is set to 0, plates will never be retransmitted.
OFFLINE MODE:
The main purpose of this mode is to detect LP with the best possible quality.
In this mode the results are available with a delay of about 2 seconds.
FREEFLOW MODE:
This mode is designed for freeflow operation. Still considering the Minimum Detections parameter, the camera tries to
read as quickly as possible without generating too much latency. Results may become available with a delay of up to
1.5 seconds.
The difference to Parking Mode is a larger internal Buffer Size, which increases reading quality at the cost of a higher
delay of results.