EasyManuals Logo

Nedap ANPR LUMO User Manual

Nedap ANPR LUMO
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
ANPR LUMO | installation guide
37/45
'4'
010100
'E'
011110
'O'
101000
'Y'
110010
'5'
010101
'F'
011111
'P'
101001
'Z'
110011
'6'
010110
'G'
100000
'Q'
101010
'7'
010111
'H'
100001
'R'
101011
'8'
011000
'I'
100010
'S'
101100
« empty »
000000
'9'
011001
'J'
100011
'T'
101101
« other »
111111
Examples:
License plate 'HK55EVB':
License plate 'VR46#T':
7.3.13 WIEGAND MATCHLIST
In the WIEGAND MATCHLIST ACTION you can define the Wiegand output. These settings are used to send the Wiegand
ID defined in the WIEGAND MATCHLIST ACCESS LIST.
The following items can be configured:
WIEGAND OUTPUT LENGTH The length of the complete Wiegand string in bits.
USE FACILITY CODE Should the facility-code be included in the Wiegand string.
FACILITY CODE The facility code value.
FACILITYCODE BITS The amount of bits used for the facility-code.
ADD PARITY BITS Should the parity bits be included in the string.
In the example above the Wiegand length is set top 34 bits, the facility code is not send, and there are no parity bits
added.
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
0
0
1
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
1
0
1
0
1
1
1
1
0
1
1
0
1
1
B
V
E
5
5
K
H
«empty»
«empty»
«empty»
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
1
1
1
1
0
1
0
1
1
0
1
0
1
0
0
0
1
0
1
1
0
1
1
1
1
1
1
1
0
1
1
0
1
T
#
6
4
R
V
«empty»
«empty»
«empty»
«empty»

Other manuals for Nedap ANPR LUMO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nedap ANPR LUMO and is the answer not in the manual?

Nedap ANPR LUMO Specifications

General IconGeneral
BrandNedap
ModelANPR LUMO
CategoryWireless Access Point
LanguageEnglish