10.2 Problems / Possible Cause / Solution
Problems
Possible Cause
Solution
Major physical or
electrical damage is
evident when the
sheet metal covers are
removed.
Contact your local authorized
Nelson Field Service Facility for
technical assistance
If all
recommended
misadjustment
have been
checked and the
problem persists,
con- tact your
local Nelson
Authorized Field
Ser- vice Facility.
Input fuses keep
blowing, or input
breaker keeps
tripping.
Make certain that the fuses or
breakers are properly sized. See
rating section of the manual for
recommended fuse and breaker
size.
Welding procedure is drawing too
much output current, or duty cycle is
too high. Reduce output current,
duty cycle, or both.
There is internal damage to the
power source. Contact an
Authorized Nelson Field Service
Facility
Machine will not power
up (no lights)
Make certain that the power switch
is in the "ON" position.
The 1.5-amp fuses may have
opened. Check fuses.
Fuses are located inside the unit. 1.5A,
600V, Part-No. 715-039-001. See chapter
9.5 „Horizontal panel assembly“
Warning!
Opening the welding unit may
only be carried out by an
authorised electrical specialist!
Machine wont weld,
can’t get any output
If the displays are not lit refer to
machine will not power up section.
If the thermal symbol is lit refer to
the thermal section.

Table of Contents