Tucker GmbH, Mail / Post: Max-Eyth-Str.1, 35394 Gießen, Germany
set a target cable resistance.
6.15 Constant Energy*
When F60 is enabled, the unit will attempt to deliver constant energy to the weld to
compensate for lift height variation, flux load size and protrusion variation, zinc
coating thickness variation, oil or oxide sur‐ face contamination, or clean and primer
coated surface with the same welding procedure. To use this function,
• Set a time and current preset with desired parameters.
• Perform a good weld
• Store a target using F32
• Enable F60 (constant power)
• Perform a weld
• Weld time will be adaptively adjusted to keep a fairly consistent weld energy and
melting
* Patent Pending