10.3.10
E010 Capacitor Voltage Could Not Be Read
Fatal, meaning you have to power down to continue welding
No
Acknowledge, meaning the error will exist as long as the unit is
powered on.
(Note, welding can continue while the error exists)
No
Description: The voltage-to-frequency signal as provided by the switch boards
to
the control board are not within a 'window' defined by the control
board
(indicating that they are invalid, or caused by noise on the signal
line).
Likely problems or items to check - in order from most likely to least
likely:
1. Inspect V-F wiring from switch board to control board. Keep
wiring away from
high power wires.
2. Eliminate possible sources of external electrical noise on the same
circuit as this
welder.
3. Replace switch board.
4. Replace control board.