EasyManua.ls Logo

Neoway M590E - General Commands; Querying Manufacturer and Version; Querying Signal Quality

Neoway M590E
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Neo_M590E V1 GPRS Module AT Command Set
Copyright © Neoway Technology Co., Ltd
2
1 General Commands
1.1 Querying the Manufacturer: I
Description
To query the manufacturer information, including manufacturer, model, and version
Format
ATI<CR>
Parameter
N/A
Return Value
<CR><LF><Manufacturer>
<CR><LF><Module mode>
<CR><LF> <Version>
<CR><LF>OK<CR><LF>
Example
ATI
NEOWAY
M590 V1
REVISION V001
OK
Manufacturer
Module mode
Version
Remarks
N/A
1.2 Querying the Version: +GMR
Description
To query the software version
Format
AT+GMR<CR>
Parameter
N/A
Return Value
<CR><LF>+GMR: <version>
<CR><LF>OK<CR><LF>
Example
AT+GMR
+GMR: M590_1169_R9S63000_V001
OK
Query the version of the software.
Remarks
N/A
1.3 Querying Signal Quality: +CSQ
Description
To check the receiving signal strength indication (RSSI) and the bit error rate (BER) of the
channel
Format
AT+CSQ<CR>
Parameter
N/A

Table of Contents

Related product manuals