* The Primary and Secondary telephone numbers are normally
only used for central station monitoring. These numbers can
only be programmed in Installer Program Mode.
** The Follow Me Telephone Number replaces the Primary AND
Secondary telephone numbers.
MONITORED
PREMISES
AUDIBLE MONITORING
TELEPHONE LINE ANY TELEPHONE
AUDIBLE MONITORING
The D16 can also be programmed to send audible
messages to any telephone or mobile phone.
When programmed for audible monitoring, the D16 calls
a pre-programmed number (or numbers) and sounds a
series of beeps over the phone. These beeps can identify
the zone or zones which caused the alarm and well as
several other alarm types.
FOLLOW ME TELEPHONE NUMBER
The Follow Me Telephone Number is the telephone
number to which the D16 sends alarm reports when
Audible Monitoring is enabled.
The Follow Me Telephone Number can be changed by
the user in User program Mode.
If the Follow Me Telephone Number is programmed, the
Primary and Secondary telephone numbers are ignored,
even if programmed. (When Audible Monitoring is
enabled).
See page 19 for information on programming the Follow
Me Telephone Number.
AUDIBLE MONITORING SEQUENCE
When triggered by an alarm, the D16 will dial the
programmed telephone number/s and output the audible
message for 45 seconds or until it is acknowledged.
ACKNOWLEDGING THE ALARM
The person receiving the call can then acknowledge the
alarm by pressing the key on their telephone. Press
the key for at least 2 seconds during pauses in the
audible message.
If the alarm is not acknowledged, the keypad’s LINE light
will flash continuously until the panel is next Armed.
CENTRAL STATION MONITORING
The D16 control panel has an on-board digital
dialler which can send detailed alarm messages
to a Central Monitoring Station.
The digital messages can include information
about the zone or zones which caused the
alarm, tamper alarms, low battery or mains
failure reports, and it can also (by user
number) identify the users who Arm and Disarm
the system.
Central Station Monitoring is highly
recommended and is the most effective method
of monitoring your D16 alarm system. For
further information about 24 hour monitoring,
contact your installer or Ness Security
Products.
MONITORING
MONITORED
PREMISES
CENTRAL STATION MONITORING
TELEPHONE LINE
MONITORING
STATION