Transition Networks Contra Converter Quick Setup Guide
Command: Set Up Remote CES Link
Syntax: CES link setup remote <link> [disable|both|rxonly|txonly] [<remoteip>]
[<remotelink>] [<remoteip2>]
Description: Update the remote configuration parameters of a logical link, where:
<link> : Logical Link number (1 to 128, may be less on some products)
disable|both|rxonly|txonly: Logical Link Direction
<remoteip> : Remote IP Address
<remotelink> : Remote Link (1-128)
<remoteip2> : 2nd Remote IP Address
Example: Update the remote configuration parameters of logical link 1:
>ces link setup remote 1 rxonly 192.168.1.110 2 192.168.1.200
Unicast IP Address has been entered
CES LINK 1 CONFIGURATION
========================
Name : FirstLL
Direction : Rx Only
Frames Per Packet : 1
Remote Packet Address : 192.168.1.110
2nd Remote Packet Address : 192.168.1.200
Remote Logical Link : 2
Jitter Buffer Length : 1 ms
Jitter Packets : 8
QOS Type : Diffserv
QOS Value : 0 (0x00)
Diffserv Codepoint : 0
VLAN Tagging : Disabled
VLAN Tagging ID : 0
VLAN Tagging Priority : 0
>
>ces link setup remote 1 both 192.168.1.110 2 192.168.1.200
Unicast IP Address has been entered
CONFIGURATION FAILED:
2nd Remote IP Address only valid on Rx Only Links.
>
33604 Rev. A www.transition.com Page 48 of 72