MRP Setting: From the Switching -> MRP tab. verify the MRP configuration Shows MVRP, MMRP, and MSRP modes
as enabled. Max fan in ports set to a default value of 0.
MRP Timers: From the Advanced->MRP Port Settings, verify Join, Leave, and Leave All timers are at Biamp settings.
Join 20, Leave 500, and Leave All 2500
Note: Default MSRP Leave Timer updated to 500cs / 5000ms to improve compatibility for large AVB networks.
Copyright 2013-2020 Biamp Systems http://support.biamp.com/