NB3700 User Manual 3.8
Parameter Serial Settings
Hardware flow control You may enable RTS/CTS hardware flow control, so that
the RTS and CTS lines are used to control the flow of data
Protocol on TCP/IP You may choose the IP protocols Telnet or TCP raw for the
device server
Port The TCP port for the device server
Timeout The timeout until a client is declared as disconnected
Parameter Server Settings
Protocol on IP port Selects the desired IP protocol (TCP or Telnet)
Port Specifies the TCP port on which the server will be available
Timeout The time in seconds before the port will be disconnected if
there is no activity on it. A zero value disables this function.
Allow remote control Allow remote control (ala RFC 2217) of the serial port
Show banner Show a banner when clients connect
Stop bits Specifies the number of stop bits used to indicate the end
of a frame
Allow clients from Specifies which clients are allowed to connect to the server
Please note that the device server does not provide authentication or encryption and
clients will be able connect from everywhere. Please consider to restrict access to a
limited network/host or block packets by using the firewall.