Configuring The Meter
4
41
4.13 USING OUTPUT SCALE AND OFFSET OT.S.O
Refer to Table 6-1 for a summary list of menu configuration.
Output Scale and Offset OT.S.O is not active unless your meter has analog output
capabilities. The menu will display whether analog output is present or not. Output Scale
and Offset OT.S.O scales your analog output to be equal to the meter's display and/or
any engineering units you require. You may scale the output for direct (4-20 mA, 0-10 V,
etc) or reverse acting (20-4 mA, 10-0 V, etc).
1. Press the MENU button until OT.S.O displays.
2. Press the TARE button. RD1 (Read 1) displays.
This is your first point of display reading.
3. Press the TARE button again. The meter shows the last previously stored
4-digit number (-1999 through 9999) with flashing 4th digit.
4. Press the ßMAX button to change the digits.
5. Press the TARE button to scroll to the next digit.
6. Press the MENU button to store your selection. OUT.1 (Output 1) displays.
This starting analog signal corresponds to your Read 1 display.
7. Press the TARE button. Selected output displays.
If you select O.2=V for voltage, the maximum signal you may select is
10.00 for an 0-10 Vdc signal output. If you select O.2=C for current, the
maximum signal you may select is 20.00.
8. Press the ßMAX button to enter the Output 1 signal selection. If you continue to
press the ßMAX button, the flashing digit's value continues to change.
9. Press the TARE button to scroll to the next digit.
10. Press the MENU button to store your selection. RD!2 (Read 2) displays.
This is your second point of display reading.
Note
Note
Note
Note
Note
Downloaded from Elcodis.com electronic components distributor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Newport Electronics INFCP-B Series and is the answer not in the manual?

Newport Electronics INFCP-B Series Specifications

General IconGeneral
BrandNewport Electronics
ModelINFCP-B Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals