Accessory card AXC 40
This accessory is used to enable connection and control of
shunt controlled additional heat, step controlled additional
heat, external circulation pump or ground water pump.
Part no. 067 060
Active/Passive cooling HPAC 40
The accessory HPAC 40 is a climate exchange module that
is to be included in a system with F1155.
Part no. 067 076
Auxiliary relay HR 10
Auxiliary relay HR 10 is used to control external 1 to 3 phase
loads such as oil burners, immersion heaters and pumps.
Part no 067 309
Base extension EF 45
This accessory is used to create a larger connection area
under F1155.
Part no. 067 152
Buffer vessel UKV
UKV 100
Part no. 088 207
UKV 40
Part no. 088 470
UKV 300
Part no. 080 301
UKV 200
Part no. 080 300
UKV 500
Part no. 080 302
Communications module MODBUS 40
MODBUS 40 enables F1155 to be controlled and monitored
using a DUC (computer sub-centre) in the building. Com-
munication is then performed using MODBUS-RTU.
Part no 067 144
Communications module SMS 40
When there is no internet connection, you can use the ac-
cessory SMS 40 to control F1155 via SMS.
Part no 067 073
Docking kit Solar 40
Solar 40 means that F1155 (together with VPAS) can be
connected to solar heating.
Part no 067 084
Docking kit Solar 42
Solar 42 means that F1155 (together with VPBS) can be
connected to solar heating.
Part no 067 153
Exhaust air module NIBE FLM
NIBE FLM is an exhaust air module designed to combine
recovery of mechanical exhaust air with ground source
heating.
Bracket pack FLM
Part no. 067 083
NIBE FLM
Part no. 067 011
External electric additional heat ELK
These accessories require accessories card AXC 40 (step
controlled addition).
ELK 213
7-13 kW, 3 x 400 V
Part no. 069 500
ELK 15
15 kW, 3 x 400 V
Part no. 069 022
Extra shunt group ECS 40/ECS 41
This accessory is used when F1155 is installed in houses
with two or more different heating systems that require
different supply temperatures.
ECS 41 (approx. 80-250
m²)
Part no 067 288
ECS 40 (Max 80 m²)
Part no 067 287
Filling valve kit KB 32
Valve kit for filling brine in the collector hose. Includes
particle filter and insulation.
KB 32 (max. 30 kW)
Part no 089 971
Free cooling PCS 44
This accessory is used when F1155 is installed in an install-
ation with passive cooling.
Part no 067 296
Gas accessory
Communications module OPT 10
OPT 10 is used to enable connection and control of gas
boiler NIBE GBM 10-15.
Part no. 067 513
61Chapter 11 | AccessoriesNIBE F1155
11 Accessories

Other manuals for Nibe F1155 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1155 Series and is the answer not in the manual?

Nibe F1155 Series Specifications

General IconGeneral
RefrigerantR410A
Control SystemNIBE SMO 40
InstallationIndoor
Heating Capacity1.5-16 kW
Cooling CapacityNot applicable
Power Input CoolingNot applicable
EER CoolingNot applicable
Weight Outdoor UnitNot applicable
Dimensions Outdoor Unit (HxWxD)Not applicable
Dimensions Indoor Unit (HxWxD)600 x 620 mm