Page #43 background imageLoading...
Page #43 background image
Menu 7.1 - update firmware
update firmware7.1
start updating
choose another file
This allows you to update the software in F1226.
NOTE
For the following functions to work the USB
memory must contain files with software for
F1226 from NIBE.
The fact box at the top of the display shows information
(always in English) of the most probable update that the
update software has selected form the USB memory.
This information states which product the software is
intended for, the software version and general informa-
tion about them. If you wish to select another file than
the one selected, the correct file can be selected by
"choose another file".
start updating
Select “start updating" if you want to start the update.
You are asked whether you really want to update the
software. Respond "yes" to continue or "no" to undo.
If you responded"yes" to the previous question the up-
date starts and you can now follow the progress of the
update on the display. When the update is complete
F1226 restarts.
NOTE
A software update does not reset the menu
settings in F1226.
NOTE
If the update is interrupted before it is complete
(for example power cut etc.), the software can
be reset to the previous version if the OK button
is held in during start up until the green lamp
starts to illuminate (takes about 10 seconds).
choose another file
update firmware7.1
Select “choose another file" if you do not want to use
the suggested software. When you scroll through the
files, information about the marked software is shown
in a fact box just as before. When you have selected a
file with the OK button you will return to the previous
page (menu 7.1) where you can choose to start the up-
date.
Menu 7.2 - logging
logging7.2
activated
interval
sec
5
Setting range: 1 s 60 min
Factory setting range: 5 s
Here you can choose how current measurement values
from F1226 should be saved onto a log file on the USB
memory.
1. Set the desired interval between loggings.
2. Tick activated".
3. The present values from F1226 are saved in a file in
the USB memory at the set interval until activated"
is unticked.
NOTE
Untick "activated" before removing the USB
memory.
43Chapter 9 | ServiceNIBE F1226

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1226 series and is the answer not in the manual?