cooling settings (accessory required)
FRROLQJ 
FRROLQJ IORZ WHPS DW  r&
FRRODQW IORZ OLQH DW r&
WLPH EHWZ VZLWFK KHDWFRRO
FORVH PL[ YDOYHV LQ FRRO PRGH
PLQ WHPS FRROLQJ IORZ
XVH URRP VHQVRU
r&
KUV
r&
r&
min. temp. cooling flow
Setting range: 5 - 50 °C
Default value: 10
cooling flow temp. at +20 °C
Setting range: 5 - 50 °C
Default value: 20
coolant flow line at +40°C
Setting range: 5 - 50 °C
Default value: 15
time betw. switch heat/cool
Setting range: 0 - 48 h
Default value: 2
heat at room under temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
cool at room over temp.
Setting range: 0.5 - 10.0 °C
Default value: 1.0
Menu
1.9.5
You can use F1245 to cool the house during hot periods of the year.