When the pool temperature drops below the set start temperature and there
is no hot water or heating requirement, F1245 starts pool heating.
Untick "activated" to switch off the pool heating.
Caution
The start temperature cannot be set to a value that is higher than the stop
temperature.
op. mode
RS PRGH
DXWR
PDQXDO
DGG KHDW RQO\
op. mode
Setting range: auto, manual, add. heat only
Default value: auto
functions
Setting range: compressor, addition, heating, cooling
Menu
4.2
The heat pump operating mode is usually set to "auto". It is also possible to
set the heat pump to "add. heat only", but only when an addition is used,
or "manual" and select yourself what functions are to be permitted.
Change the operating mode by marking the desired mode and pressing the
OK button. When an operating mode is selected it shows what in the heat
pump is permitted (crossed out = not permitted) and selectable alternatives
to the right. To select selectable functions that are permitted or not you mark
the function using the control knob and press the OK button.
59NIBE™ F1245Chapter 3 | F1245 – at your service