Low room temperature
Closed thermostats in several rooms.
Set the thermostats to max in as many rooms as possible. Adjust the
room temperature via menu 1.1 instead of choking the thermostats.
Heat pump in incorrect operating mode.
Enter menu 4.2. If mode "auto" is selected, select a higher value on
"stop heating“ in menu 4.9.2.
If mode "manual" is selected, select "heating". If this is not enough,
select "addition".
Too low set value on the automatic heating control.
Enter menu 1.1 (temperature) and adjust the heat curve offset of the
heat curve. If the room temperature is only low in cold weather the
curve slope in the menu 1.9.1 (heating curve) needs to be adjusted
up.
Too low or no operating prioritisation of heat.
Enter menu 4.9.1 and increase the time for when heating is to be
prioritised.
Holiday mode activated in menu 1.3.4.
Enter menu 1.3.4 and select “Off”.
External switch for changing the room heating activated.
Check any external switches.
Air in the climate system.
Vent the climate system.
Closed valves to the climate system.
Open the valves.
High room temperature
Too high set value on the automatic heating control.
Enter menu 1.1 (temperature) and adjust the heat curve offset
downwards. If the room temperature is only high in cold weather the
curve slope in menu 1.9.1 (heating curve) needs to be adjusted down.
External switch for changing the room heating activated.
Check any external switches.
Low system pressure
Not enough water in the climate system.
NIBE™ F1245Chapter 4 | Disturbances in comfort72

Other manuals for Nibe F1245

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1245 and is the answer not in the manual?

Nibe F1245 Specifications

General IconGeneral
RefrigerantR410A
Control SystemNIBE SMO 40
Dimensions (HxWxD)1800 x 600 x 620 mm
Energy Efficiency Class Heating 35°CA++
Energy Efficiency Class Heating 55°CA++
Heating Capacity5-12 kW
COP Heating4.5
Integrated Hot Water Tank180 liters
Power Input Heating1.0 - 3.0 kW

Related product manuals