Degree minutes are a measurement of the current heating requirement in
the house and determine when the compressor respectively additional heat
will start/stop.
Caution
Higher value on "start compressor" gives more compressor starts, which in-
creases wear in the compressor. Too low value can give uneven indoor
temperatures.
factory setting user
'R \RX ZDQW WR UHVHW DOO XVHU VHWWLQJV WR
IDFWRU\ VHWWLQJV"
IDFWRU\ VHWWLQJ XVHU 
\HV
QR
Menu
4.9.4
All settings that are available to the user (including advanced menus) can be
reset to default values here.
Caution
After factory setting, personal settings such as heating curves must be reset.
67NIBE™ F1245Chapter 3 | F1245 at your service