auto mode setting
VWDUW FRROLQJ
VWRS KHDWLQJ
VWRS DGGLWLRQDO KHDW
ILOWHULQJ WLPH
r&
r&
r&
KUV
DXWR PRGH VHWWLQJ
start cooling
Setting range: -20 – 40 °C
Default value: 25
stop heating
Setting range: -20 – 40 °C
Default values: 20
stop additional heat
Setting range: -20 – 40 °C
Default values: 15
filtering time
Setting range: 0 – 48 h
Default value: 24 h
Menu
4.9.2
When operating mode is set to "auto“ the heat pump selects when start and
stop of additional heat and heat production is permitted, dependent on the
average outdoor temperature. If accessories for cooling are present or if the
heat pump has the integrated cooling function you can also select the start
temperature for cooling.
Select the average outdoor temperatures in this menu.
You can also set the time over which (filtering time) the average temperature
is calculated. If you select 0, the present outdoor temperature is used.
65NIBE™ F1245Chapter 3 | F1245 – at your service