Top up the water in the climate system.
Low or a lack of ventilation
This part of the fault-tracing chapter only applies if the NIBE FLM accessory
is installed.
Filter blocked.
Exhaust air device blocked or throttled down too much.
Fan speed in reduced mode.
Enter menu 1.2 and select “normal".
External switch for changing the fan speed activated.
Check any external switches.
High or distracting ventilation
This part of the fault-tracing chapter only applies if the NIBE FLM accessory
is installed.
The ventilation is not adjusted.
Order ventilation adjustment.
Fan speed in forced mode.
Enter menu 1.2 and select “normal".
External switch for changing the fan speed activated.
Check any external switches.
Filter blocked.
Clean or replace the filter.
The compressor does not start
There is no heating requirement.
The heat pump does not call on heating nor hot water.
Minimum time between compressor starts has not been reached.
Wait 30 minutes and check if the compressor has started.
Alarm tripped.