ADDRESSING VIA CASCADE CONNECTION
On the communication board (AA23-S3), the communic-
ation address is selected for F2040 to the control mod-
ule. The default address for F2040 is 1. In a cascade
connection, all F2040 must have a unique address. The
address is coded in binary.
S3:3S3:2S3:1Address
OFFOFFOFF1
OFFOFFOn2
OFFOnOFF3
OFFOnOn4
OnOFFOFF5
OnOFFOn6
OnOnOFF7
OnOnOn8
NIBE F2040Chapter |42