Readjusting, heating
medium side
Air is initially released from the hot water and venting
may be necessary. If bubbling sounds can be heard from
the heat pump, the circulation pump and radiators the
entire system will require further venting. When the
system is stable (correct pressure and all air eliminated)
the automatic heating control system can be set as re-
quired.
Adjustment, charge
flow
Instructions for adjusting hot water charging are in the
Installer Manual for the relevant indoor module. See
page 59 for the list of the indoor units and accessories
that can be connected to F2040.