Energy labelling
INFORMATION SHEET
NIBESupplier
F2040-16F2040-12F2040-8F2040-6Model
35 / 5535 / 5535 / 5535 / 55°CTemperature application
A++ / A++A++ / A++A++ / A++A++ / A++Seasonal space heating energy efficiency class, aver-
age climate
15 / 1412 / 108 / 75 / 5kWRated heat output (P
designh
), average climate
6,702 / 8,4315,382 / 6,1363,882 / 4,4472,089 / 3,248kWhAnnual energy consumption space heating, average
climate
176 / 134174 / 132172 / 127188 / 131%Seasonal space heating energy efficiency, average
climate
35353535dBSound power level L
WA
indoors
15 / 1612 / 139 / 104 / 6kWRated heat output (P
designh
), cold climate
15 / 1512 / 128 / 84 / 5kWRated heat output (P
designh
), warm climate
10,040 / 13,6297,798 / 11,1976,264 / 8,8442,694 / 4,610kWhAnnual energy consumption space heating, cold cli-
mate
3,370 / 4,1832,759 / 3,4191,879 / 2,333872 / 1,398kWhAnnual energy consumption space heating, warm cli-
mate
144 / 113142 / 111139 / 108143 / 116%Seasonal space heating energy efficiency, cold climate
235 / 189229 / 185225 / 180252 / 179%Seasonal space heating energy efficiency, warm cli-
mate
61575450dBSound power level L
WA
outdoors
DATA FOR ENERGY EFFICIENCY OF THE PACKAGE
F2040-16F2040-12F2040-8F2040-6Model
SMOSMOSMOSMOControl module model
35 / 5535 / 5535 / 5535 / 55°CTemperature application
VIController, class
4.0%Controller, contribution to efficiency
180 / 138178 / 136176 / 131192 / 135%Seasonal space heating energy efficiency of the
package, average climate
A+++ / A++A+++ / A++A+++ / A++A+++ / A++Seasonal space heating energy efficiency class of the
package, average climate
148 / 117146 / 115143 / 112147 / 120%Seasonal space heating energy efficiency of the
package, cold climate
239 / 193233 / 189229 / 184256 / 183%Seasonal space heating energy efficiency of the
package, warm climate
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to
the package, the overall efficiency of the package should be recalculated.
71Chapter 12 | Technical dataNIBE F2040

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F2040 Series and is the answer not in the manual?

Nibe F2040 Series Specifications

General IconGeneral
SeriesF2040
RefrigerantR410A
COPUp to 5.0 (depending on model and operating conditions)
Sound Power Level Indoor UnitN/A (Requires separate indoor unit)
Operating Temperature Range Cooling+10°C to +43°C
Dimensions Indoor Unit (HxWxD)N/A (Requires separate indoor unit)
TypeAir Source Heat Pump