Transport and storage
F2040 must be transported and stored vertically.
Assembly
Place F2040 outdoors on a solid level base that can
take the weight, preferably a concrete foundation. If
concrete slabs are used they must rest on asphalt or
shingle.
The concrete foundation or slabs must be positioned
so that the lower edge of the evaporator is at the level
of the average local snow depth, although a minimum
of 300 mm.
The F2040 should not be positioned next to sensitive
walls, for example, next to a bedroom.
Also ensure that the placement does not inconveni-
ence the neighbours.
F2040 must not be placed so that recirculation of the
outdoor air can occur. This causes lower output and
impaired efficiency.
The evaporator should be sheltered from direct wind,
which negatively affects the defrosting function. Place
F2040 protected from wind against the evaporator.
Large amounts of condensation water, as well as melt
water from defrosting, may be produced. Condensa-
tion water must be led off to a drain or similar (see
page 10.
Care must be exercised so that the heat pump is not
scratched during installation.
LEK
LEK
LEK
Cirka 1 m
LEK
LEK
LEK
Cirka 1 m
min 300 mm
Min. 300 mm
Do not place F2040 directly on the lawn or other non
solid surface.
If there is a risk of snow slip from roof, a protective roof
or cover must be erected to protect the heat pump,
pipes and wiring.
9Chapter 2 | Delivery and handlingNIBE F2040
2 Delivery and handling

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F2040 Series and is the answer not in the manual?

Nibe F2040 Series Specifications

General IconGeneral
SeriesF2040
RefrigerantR410A
COPUp to 5.0 (depending on model and operating conditions)
Sound Power Level Indoor UnitN/A (Requires separate indoor unit)
Operating Temperature Range Cooling+10°C to +43°C
Dimensions Indoor Unit (HxWxD)N/A (Requires separate indoor unit)
TypeAir Source Heat Pump

Related product manuals