EasyManua.ls Logo

Nibe FIGHTER 410P - Technical Specifications

Nibe FIGHTER 410P
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
FIGHTER 410P
32
IP 21
Rated output, compressor 650 W
Required headroom 2 185 mm
Depth 615 mm
Volume total 240 litres
Volume water heater 170 litres
Output immersion heater 8,0 kW (switchable)
Rated output exhaust air fan 170 W
Max pressure in storage heater 0,9 MPa (9 (bar)
Breaking value, low pressure pressostat 0,15 MPa (1.5 (bar)
Design pressure in double jacket volume 0,25 MPa (2.5 (bar)
Refrigerant type R290 (propane)
Cut-out temperature compressor 54 °C
Cut-out temperature, temperature limiter for immersion heater 88 °C
Cut-out temperature, temperature limiter for compressor 88 °C
Cut-out temperature immersion heater 52 – 65 °C *(52 – 60)
Sound level in room where installed 47 – 50 dBA
Height (excl. foot: 15 – 40 mm) 2 095 mm
Width 600 mm
Weight 200 kg
Volume double jacket 70 litres
Supply voltage 230 V~ 1-phase + N
Rated output, circulation pump 100 W
Rated output supply air fan 170 W
Enclosure class IP 21
Breaking value, high pressure pressostat 2,45 MPa (24.5 (bar)
Max pressure in double jacket volume 0,25 MPa (2.5 (bar)
Refrigerant volume 495 g
Cut-in temperature compressor 51 °C (Controlled by separate sensor)
Cut-in temperature immersion heater 49 – 62 °C *(49 – 57)
* See the section Electrical connection — Blocking immersion heater operation
For the Installer
Inlet temperature 40 °C
COP 2,60
Total Power input 0,715 kW
Exhaust air:
Air flow 150 m
3
/h
Inlet wet bulb temperature 12 °C
COP and heating capacity according to EN 14511-2:2004
Heating capacity 1,75 kW
Current 3,6 A
Rating condition:
Inlet dry bulb temperature 20 °C
Water:
Outlet temperature 45 °C

Table of Contents