Troubleshooting
If the malfunction does not appear in the display or NIBE
FLM is not connected to a compatible heat pump, the
following tips can be used:
BASIC ACTIONS
Start by checking the following items:
That the heat pump is running or that the supply cable
to NIBE FLM is connected.
Group and main fuses of the accommodation.
The property's earth circuit breaker.
LOW OR A LACK OF VENTILATION
Filter (HQ10) blocked.
Clean or replace the filter.
The ventilation is not adjusted.
Order/implement ventilation adjustment.
Exhaust air device blocked or throttled down too
much.
Check and clean the exhaust air devices.
Fan speed in reduced mode.
If NIBE FLM is connected to a compatible heat
pump: Enter menu 1.2 and select “normal”.
If NIBE FLM is connected to another heat pump:
Check the potentiometer (SF3).
External switch for changing the fan speed activated.
Check any external switches.
HIGH OR DISTRACTING VENTILATION
Filter (HQ10) blocked.
Clean or replace the filter.
The ventilation is not adjusted.
Order/implement ventilation adjustment.
Fan speed in forced mode.
If NIBE FLM is connected to a compatible heat
pump: Enter menu 1.2 and select “normal”.
If NIBE FLM is connected to another heat pump:
Check the potentiometer (SF3).
External switch for changing the fan speed activated.
Check any external switches.
GURGLING SOUND
Not enough water in the water seal.
Refill the water seal with water.
Choked water seal.
Check and adjust the condensation water hose.
NIBE FLMChapter 9 | Disturbances in comfort30