NOTE
VVM 320 must be filled with water before the
phase sequence is detected.
For the heat pump to disconnect the electrical output
in the correct phase, the phase sequence must have
been detected during the installation. In the menu
5.1.12 the phase sequence must be detected after-
wards. An unsuccessful detection may be due to the
current sensors not being correctly connected or that
other electrical equipment started or stopped during
detection.
Factory settingNameMenu
16Afuse size5.1.12
detect phase order
1-phase inverter stepping out:
Variant of load monitor designed to be used in in-
stances where 1-phase inverters are used.
Compressors together with 3-phase disconnectable
additional heat:
Load monitor initially disconnects the immersion
heater's output. Finally the heat pump frequency is
reduced.
If this phase is used to drive 1-phase inverter com-
pressor:
Initially, the step-controlled additional heat is discon-
nected from this phase as per the section above regard-
ing disconnecting the step-controlled additional heat.
If the electrical power still exceeds the set value the
compressor slows to 20 Hz per 30 seconds until the
electrical power falls below the set value.
External connection options
AUX inputs
There are 5 x external inputs with selectable function.
Connected on AA3-X6:9-18.
The selectable functions are activated in menu 5.4.
Selectable functions that are active when the input is
connected:
AUX1-5
Not used.
Activate temporary lux
External adjustment
Block additional heat
Blocking Compressor
Block heating
Block cooling
Cooling/heat sensor (BT74)
Tariff blocking
SG ready A
SG ready B
External alarm (NC)
External alarm (NO)
+Adjust
AUX outputs
The selectable functions on the AUX output AA3 -X7
(max 2 A) are activated in menu 5.4:
AA3-X7
Not used
Add heat in series
Alarm output
Cooling mode indication
Hot water circulation
Ext. heating medium pump
Extra additional heat in charge circuit
Controls (via the AUX output, terminal X7) additional
heat which is in series between heat pump and VVM
320. The additional heat controls in one step and is in-
tended to support the installation when the heat pump
is stationary.
The additional heat must be dimensioned so that it is
in proportion to the installed heat pump. Because the
additional heat output is not known and an output is
required for the pump regulator, 7,5 kW is assumed.
If add heat in series” is selected on the AUX output
and the degree minutes are less than the selected value
in menu 4.9.3 start compressor”, the AUX relay opens
during the following:
Red light alarm from heat pump
Communication alarm from heat pump.
Cold outdoor air, heat pump.
Only additional heat selected in menu 4.2.
The AUX relay must be off if the degree minutes are
greater or equal to 0 DM.
When the AUX relay is on, charge pump GP1 must run:
If the speed is set to ”manual speed” in menu
5.11.1.2, GP1 is run according to the menu settings.
If the speed is not set to ”manual speed” in menu
5.11.1.2, GP1 runs and calculates that the additional
heat in the charge circuit produces 7,5 kW. GP1 runs
as if the internal additional heat is on.
NIBE™ VVM 320Chapter 4 | Description of functions18

Table of Contents

Other manuals for Nibe VVM 320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe VVM 320 and is the answer not in the manual?

Nibe VVM 320 Specifications

General IconGeneral
Dimensions (HxWxD)1800 x 600 x 615 mm
Power Supply230 V
Frequency50 Hz
Protection classIP21
Compatible withNibe heat pumps
DisplayTouch display
Smart Home IntegrationYes, via NIBE Uplink
Operating temperature0°C to +45°C
Relative humidityMax. 95 %
TypeControl unit for heat pumps

Related product manuals