EasyManua.ls Logo

Nibe VVM 320 - Adjust the Indoor Module Settings; MY SYSTEM Configuration Overview; Plus Functions Setup; Operating Mode Selection

Nibe VVM 320
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm 71 - perm. com.error input card
Is the wiring connector (W109)
correctly connected on base card
(AA2-X5) and on the input card
(AA3-X1)?
YES
NO
Has the fault been corrected?
Replace the base card (AA2).
OK.
YES
Action.
NO
Replace the input circuit board
(AA3).
Is the wiring connector (W105)
correctly connected on input circuit
board (AA3-X2) and on the display
card (AA4-X8)?
Action.
NO
YES
NO
Has the fault been corrected?
OK.
YES
Replace the display card (AA4).
53Chapter 6 | TroubleshootingNIBE™ VVM 320

Table of Contents

Other manuals for Nibe VVM 320

Related product manuals