EB101 with On/Off control
Off and on controls VVM 320.
MiscellaneousDescriptionDefaultSelectionSettingMenu
See manual for re-
spective EB101
Minimum time in-
terval between
start and stop
20 min20-60 minutesSetting A45.11.1.1
See manual for re-
spective EB101
Balance temperat-
ure
0°C-15°C to +10°CSetting A5
See manual for re-
spective EB101
Continuous run
time before addi-
tional heat is per-
mitted
120 min1 - 120 minSetting A6
See manual for re-
spective EB101
Stop temperature-20°C-25°C to 0°CSetting A7
See manual for re-
spective EB101
Minimum running
time
See manual for re-
spective EB101
10 - 90 minSetting A8
See manual for re-
spective EB101
Start temperature
for permitted de-
frosting
-3°C-4°C to 0°CSetting A9
See manual for re-
spective EB101
Stop temperature
for defrosting
20°C10°C to 40°CSetting A10
See manual for re-
spective EB101
Manual activation
of active defrost-
ing procedure
OffOff/OnSetting A12
See manual for re-
spective EB101
Activation of the
function collar
heater
OffOff/OnSetting A14
See manual for re-
spective EB101
Activating the de-
icing fan function
OffOff/OnSetting A15
33Chapter 4 | Description of functionsNIBE™ VVM 320