6–English
English
5
MEMORISING TRANSMITTERS OR THE KEYPAD IN MODE 2
Usingthisprogrammingmode,youwillprogrammeasinglebuttonofthetransmitterorkeypadonthisautomationbyassociatingoneofthedesired
commandslistedinthetablebelow.
Using this programming mode, you can programme all the buttons of
thetransmitterorkeypadonthisautomationwiththefollowingfunctions:
T1:Open/Stop/Closefunction
T2:PedestrianOpening/Stop/Closingfunction
T3:Opening/Stopfunction
T4:Close/Stopfunction
T5:lightwithON/OFFfunction
Procedure for programming the transmitter:
01. PressbuttonP4(onthecontrolunit)foratleast3seconds.
02. ReleasethebuttonwhenLEDL4lightsup.
03. Within 10 seconds, press any button of the transmitter to be
memorisedforatleast3seconds:LEDL4mustash3times.
04. Wait10secondsforthetransmitter’smemorisation.
Procedure for programming the DS100 keypad:
01. PressbuttonP4foratleast3seconds.
02. ReleasethebuttonwhenLEDL4lightsup.
03. Within 10seconds, entercode11(oranewcode) onthe keypad
andpressbuttonBonthekeypadfor4seconds:LEDAmustash
3times.
04. Wait10secondsandthecode’skeypadwillbememorised
Thecodecanbepersonalisedbyperformingprocedure6,whichcanbe
foundinthekeypad’sinstructions.
5.1 - SELECTING THE COMMAND TO BE ASSOCIATED
WITH YOUR KEY
01. PressbuttonP4foranumberoftimescorrespondingtothechosen
command.LEDP4willashanumberoftimesequaltothedesired
function.
02. Within10seconds,pressthebuttonofthetransmitteryouwishto
associatewith thisfunction forat least3 seconds.LED L4should
ash3times.
03. Wait10secondsandthetransmitterwillbememorised.
TABLE 2 - Command memorisation
Number of button presses Associated command
Number of ashes of LED L4 on the
control unit
once
Step-by-step 1
2 times Pedestrianopening 2
3 times Pedestrian 3
4 times Closing 4
5 times Lightoutput(device)230V:ON-OFF 5
4
MEMORISING TRANSMITTERS OR THE KEYPAD IN MODE 1
A
B
C
20
Fuse 1.6A T
Flash
ECSbus
Stop
Aerial
P4
L4 L3
P3
3 s
21
Fuse 1.6A T
Flash
ECSbus
Stop
Aerial
P4
L4 L3
P3
22