7.2 SPECIAL FUNCTIONS
7.2.1 “Move anyway” function
This function can be used to operate the automation even one
or more some safety devices fail to work properly or are out of
order. The automation can be controlled in “hold-to-run” mode
by proceeding as follows:
1. send a command to move the gate, using a transmitter or
key selector, etc. If everything works properly, the boom
will move normally, otherwise proceed with point 2
2. within 3 seconds, press the control again and hold it down
3. after roughly 2 seconds, the gate will complete the re-
quested manoeuvre in “Hold-to-run mode, in other
words, it will continue to move so long as the control is
held down.
l
When the safety devices fail to work, the warn-
ing light will emit a few ashes to signal the
type of problem. To verify the type of anom-
aly, consult the “TROUBLESHOOTING...
(troubleshooting guide)” chapter.
7.2.2 “Maintenance notice” function
This function warns the user when the automation requires a
maintenance check.
The “Maintenance notice” parameter can be adjusted using the
Oview programmer.
The maintenance request signal is given through the Flash
warning light or by the maintenance indicator, depending on the
type of programming chosen.
l
The “Flash” warning light and the maintenance in-
dicator give the signals indicated in “Table 7” based
on the number of manoeuvres completed with re-
spect to the set limit.
Table 7
MAINTENANCE NOTICE THROUGH FLASH AND MAINTENANCE
INDICATOR
Number of
manoeuvres
Signal on “Flash”
Maintenance indicator
signal
Below 80% of the
limit
Normal (0.5 sec on,
0.5 sec off)
Lit for 2 seconds
at the start of the
opening manoeuvre
Between 81% and
100% of the limit
Remains lit for 2
seconds at the start
of the manoeuvre
Flashes for the
entire duration of the
manoeuvre
Exceeding 100%
of the limit
Remains lit for 2
seconds at the
start and end of the
manoeuvre then
carries on normally
Flashes always
7.2.3 Verifying the number of manoeuvres completed
The number of manoeuvres completed can be checked through
the control unit (refer to “Table 5”) or with the Oview program-
mer, under “Maintenance”.
7.2.4 Manoeuvre counter resetting
Once maintenance has been performed on the system, the ma-
noeuvre counter must be reset.
Resetting can only be done through the Oview programmer.
TROUBLESHOOTING...
(troubleshooting guide)
7
8 TROUBLESHOOTING GUIDE
8.1 TROUBLESHOOTING
The table below contains useful instructions to resolve any mal-
functions or errors that may occur during installation or in case
of a fault.
F2
F1
43

Table of Contents

Other manuals for Nice M5BAR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice M5BAR and is the answer not in the manual?

Nice M5BAR Specifications

General IconGeneral
BrandNice
ModelM5BAR
CategoryOther
LanguageEnglish

Related product manuals