Mercury 310 Automated Gate System
Installation and Programming Manual
3838
2
Force Setting
8.3 FUNCTION KNOB SETTINGS
Set to “FORCE”
+
Force
Values Default Details
0 - 5 2
Least force = 0
Most force = 5
The Force setting adjusts the amount of force the gate will exert on an immovable object before it will initiate
a “Hard Shutdown” of the system. This is a very important safety feature and settings other than the defaut
(2) should be carefully considered.
To set, place selection knob to “FORCE” and select values (0-5) using the Right or Left arrow buttons.
Use Right or Left
Arrow Button
Use the function knob to select the gate parameters for Force, Close Timer, and Leaf Delay per the instructions
2, 3, and 4.
3
Close Timer Setting
Set to “CLOSE TIMER”
+
Close Timer
Values Default Details
0 - 90
(seconds)
0
(OFF)
Increments = 1
(Press/hold = 5s
increments)
The close Timer setting determines how long the gate will remain open (0 - 90 seconds) after hitting the
open limit before automatically closing again.
Use Right or Left
Arrow Button
Mercury 310
NOTICE
Close timer does not count down after a
Type A or Type C event.