EC PROBE CLEANING
It is recommended to replace the
EC probe every 12-15 months.
You can buy the original
NIDO EC probe here:
Check the condition of the EC probe regularly (every
90-110 days) to ensure correct operation if the probe
is dirty or inaccurate.
1� Disconnect the the IN and OUT hoses.
2� Pull out the EC probe by unscrewing the press-
probe.
3� Clean the EC probe with the supplied brush.
4� Wash the EC probe under running water and dry
the outside with a clean cloth.
5� Insert the EC probe as far as it will go and press-
probe.
6� Connect the IN and OUT.