9.
Mounting
the
condenser
Mounting
the
system
condenser
turret
unit
First
you
assemble
the
system
condenser
turret
unit,
as
follows:
ELWD
condenser
Leave
the
hollow
module
(with
mark
"A")
in
the
turret
as
is.
Set
the
modules
PhL
to
Ph3
(annular
diaphragm
modules
marked
in
red),
into
the
remaining
module
ports
so
that
when
looked
from
above,
their
numbers
increase
with
clockwise
rotation
of
the
turret.
Fix
each
module
with
two
hexagonal
socket
head
screws.
Screw
the
ELWD
condenser
lens
(marked
in
red)
into
the
turret
unit.
LWD
condenser
Set
the
supplementary
lens
into
the
pocket
of
the
diascopic
illumination
unit,
(page
24)
Remove
the
hollow
module
(with
mark
“A")
from
the
turret
by
loosening
the
two
hexagonal
socket
head
screws.
(The
removed
module
A
is
used
for
bright-field
microscopy.)
Set
the
modules
PhL
to
Ph4
(annular
diaphragm
modules
marked
in
black),
into
the
module
ports
so
that
their
numbers
increase
with
clockwise
rotation
of
the
turret.
Fix
each
module
with
two
hexagonal
socket
head
screws.
Screw
the
LWD
condenser
lens
(marked
in
white)
into
the
turret
unit.
Now
you
install
the
system
condenser
turret
unit
to
the
microscope,
as
follows:
Using
the
hexagonal
screwdriver,
loosen
the
condenser
clamp
screw
(hexagonal
socket
head
screw)
located
deep
in
the
right-hand
hole
of
the
condenser
holder.
(If
the
clamp
screw
is
hidden
and
the
screwdriver
cannot
be
inserted,
loosen
the
mount
rotation
clamp
screw
on
the
left
of
the
condenser
holder,
rotate
the
mount
center
by
hand
until
the
pin
at
the
top
of
the
mount
aligns
with
the
groove
in
the
mount
center,
and
tighten
the
mount
rotation
clamp
screw
to
secure.)
Mount
the
system
condenser
turret
unit
so
that
the
mark
on
the
module
on
the
optical
path
face
the
front
side,
and
tighten
the
clamp
screw
with
the
hexagonal
screwdriver
to
secure
the
turret
unit.
Mounting
the
ELWD
condenser
Mounting
procedures
are
the
same
as
above
system
condenser
turret
unit.
Using
the
hexagonal
screwdriver,
loosen
the
condenser
clamp
screw
(hexagonal
socket
head
screw)
located
deep
in
the
right-hand
hole
of
the
condenser
holder.
(If
the
clamp
screw
is
hidden
and
the
screwdriver
cannot
be
inserted,
loosen
the
mount
rotation
clamp
screw
on
the
left
of
the
condenser
holder,
rotate
the
mount
center
by
hand
until
the
pin
at
the
top
of
the
mount
aligns
with
the
groove
in
the
mount
center,
and
tighten
the
mount
rotation
clamp
screw
to
secure.
See
above
figure.)
Mount
the
condenser
so
that
the
marks
on
the
turret
face
to
the
front
side,
and
tighten
the
clamp
screw
with
the
hexagonal
screwdriver
to
secure
the
condenser.
(See
above
figure.)