EasyManua.ls Logo

Nilfisk-Advance Advance SC750 ST

Nilfisk-Advance Advance SC750 ST
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 22
LCD
Display
Code
ST
Blink
Code
Code
Denion
Explanaon / Code Seng Condions / Flash Indicator
/ Disables / Check
32 2,5 Scrub Deck Li Actuator
Circuit Open
The Main Machine Controller is trying to move the actua-
tor but it is not sensing any current ow. (Senses <= 100
m Amps for 5 seconds).
Check Actuator, wiring.
33 3,1 Vacuum Motor Circuit
Open
The Main Machine Controller has energized the Vacuum
Contactor but it is not sensing any current ow through
the vacuum motor ground circuit for at least 5 seconds.
(Senses<= 3 Amps for 5 second and Fault Code 36 is not
acve)
Check motor, wiring.
35 3,2 Brush Contactor Coil
Circuit Open
The Main Machine Controller has aempted to energize
the Brush Contactor but it is not seeing any current ow.
(Senses <= 20 m Amps for 5 seconds).
Check for open Contactor winding, wiring.
36 3,3 Vacuum Contactor Coil
Circuit Open
The Main Machine Controller has aempted to energize
the Vacuum Contactor but it is not seeing any current
ow. if (Senses <= 20 m Amps for 5 seconds)
Check for open Contactor winding, wiring.
37 (N/A) Detergent Pump Circuit
Open
The Main Machine Controller has energized the deter-
gent pump but it is not sensing any current ow. (Senses
<= 30 m Amps for 5 seconds).
Check for open pump winding, wiring.
38 (N/A) Brush Remove Contactor
Coil Circuit Open
The Main Machine Controller has aempted to energize
the Brush Remove Contactor but it is not seeing any cur-
rent ow. (Senses <= 20 m Amps for 5 seconds)
Check for open Contactor winding, wiring.
60 3,4 Brush Motor Contactor
Stuck Closed
The Main Machine Controller is sensing current ow
through the Brush Motor ground circuit when it has not
energized the Brush Motor Contactor (Senses >= 4 Amps
for 5 seconds and Fault Code 63 is not acve)
Check for “welded” contacts.
61 3,5 Vacuum Motor Contactor
Stuck Closed
The Main Machine Controller is sensing current ow
through the Vacuum Motor ground circuit when it has
not energized the Vacuum Motor Contactor (Senses >=
3 Amps for 5 seconds and Fault Code 64 and 65 are not
acve)
Check for “welded” contacts.

Table of Contents

Related product manuals