EasyManua.ls Logo

Nilfisk-Advance Advance SC750 ST

Nilfisk-Advance Advance SC750 ST
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 23
LCD
Display
Code
ST
Blink
Code
Code
Denion
Explanaon / Code Seng Condions / Flash Indicator
/ Disables / Check
62 4,1 Soluon Solenoid Circuit
Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the soluon solenoid cir-
cuit when it has not requested that the switch be turned
on. (Senses >= 20 m Amps for 5 seconds).
63 4,2 Brush Contactor Coil
Circuit Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the Brush Contactor Coil
circuit when it has not requested that the switch be
turned on. (Senses >= 20 m Amps for 5 seconds).
64 4,3 Vacuum Contactor Coil
Circuit Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the Vacuum Contactor
Coil circuit when it has not requested that the switch be
turned on. (Senses >= 20 m Amps for 5 seconds).
65 (N/A) Brush Remove Contactor
Coil Circuit Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the Brush Remove Contac-
tor Coil circuit when it has not requested that the switch
be turned on. (Senses >= 20 m Amps for 5 seconds).
70 4,4 Corrupt Communicaon
From On-Board Baery
Charger
The Baery Charger did not properly repeat the charging
prole message back to the Main Machine Controller.

Table of Contents

Related product manuals