Form Number 56043150 Page 29
Lock Out Soluon Flow Rate - It is possible to lock out any one or more of the soluon ow rate sengs. During normal
operaon, the ow rate(s) that are locked out will not be able to be selected.
To check or change the seng:
1. While pressing and holding the vacuum and soluon switches forward and the scrub
switch backwards, turn the key switch on.
2. Wait about 3 seconds unl all of the LEDs light up and then go o. Release the switches.
The Vacuum Indicator will remain on and the Fault Indicator will be ashing a numeric value that represents the cur-
rent seng. To change the seng, press the soluon switch forward to increase the value or backwards to decrease the
value. To save the seng press the scrub switch forward (All LEDs will turn on) then turn o the key switch.
• 1 blink = No ow rate locked out.
• 2 blinks = Low ow rate locked out.
• 3 blinks = Medium ow rate locked out.
• 4 blinks = High ow rate locked out.
• 5 blinks = Low and medium ow rates locked out.
• 6 blinks = Low and high ow rates locked out.
• 7 blinks = Medium and high ow rates locked out.
Recovery Tank Full Enable/Disable – It is possible to enable or disable the Recovery Tank Full automac shuto feature.
Enable means that the automac shuto feature is turned on; disable means that the automac shuto feature is turned
o.
To check or change the seng:
1. While pressing and holding the vacuum and scrub switches backward and the soluon
switch forward, turn the key switch on.
2. Wait about 3 seconds unl all of the LEDs light up and then go o. Release the switches.
The Heavy Scrub Pressure Indicator will remain on and the Fault Indicator will be ashing a numeric value that repre-
sents the current seng. To change the seng, press the soluon switch forward to increase the value or backwards to
decrease the value. To save the seng, press the scrub switch forward (All LEDs will turn on) then turn o the key switch.
• 1 blink = Enabled
• 2 blinks = Disabled