What to do if Nobles Floor Machine has poor solution pick-up?
- SSean WilsonAug 2, 2025
If the Nobles Floor Machine exhibits poor solution pick-up, several factors could be responsible. Check the recovery tank cover gasket for defects and replace it if necessary. Inspect the float shut-off screen for clogs and remove any lint. Ensure the accessory tool vacuum hose port cover is securely in place. Tighten any loose vacuum hose connections under the cover and replace any defective vacuum hoses. Secure the cuffs to the hose. Also, consider slowing down the cleaning process.