local-url — [cflash-id/][file-path]
cflash-id — cf1:, cf2 (only on 7210 SAS-T)
virtual-chassis
Syntax virtual-chassis {slotid | slotid-range} image-sync
Context admin
Supported
Platforms
7210 SAS-Sx 1/10GE standalone-VC, 7210 SAS-S 1/10GE: standalone-VC
Description This command upgrades the boot.tim file on the IMM-only node in a virtual chassis (VC) and
ensures that on the next reboot of the node, the newer bootloader image is used to boot the
system. Bootloader images are copied to all the available storage locations on the card,
ensuring that a back up copy is available in the event that the primary storage device fails.
The boot.tim file can be upgraded on a single IMM-only node or on a range of IMM-only nodes
in a VC.
The image-sync keyword initiates image synchronization of the IMM-only node. It copies the
boot.tim from the active CPM to the card/node identified by the slot-id or slotid-range
parameter.
Parameters slotid — Specifies the card slot number.
Values 1 to 8
slotid-range — Specifies the card slot numbers for a range of cards.
Values 1 to 8
image-sync — Keyword to initiate image synchronization of the IMM-only node.