After Sales
Technical Documentation
RAE/RAK–1N
Service Software
Page 7– 20
Amendment 1 04/97
3.1.1 – Active Unit
Either receiving or transmission tests can be selected. When TX is
selected, Data transmission is activated :
If operation mode is continuous,
– Continuous mode is changed to burst mode,
If operation mode is burst,
– TX power is activated
– TX channel is activated
Information window is updated
When RX is selected, Data transmission is deactivated
TX power is deactivated
if operation mode is continuous,
– AGC is controlled
– Continuous mode RX channel is activated
If operation mode is burst,
– RX and monitoring channel are activated
Information window is updated
3.1.2 – TX Power Level
With this function it is possible to change the transmission power. When
the selection is made, the user can give the needed GSM power value
(5...15) or select the test value, which is tuned with TX power tuning
function. The test value selection is made by writing ”test” with small or
capital letters.