After Sales
Technical Documentation
RAE/RAK–1N
RF
Page 3– 9
Amendment 1 04/97
Control Signals
In the following tables (Table 2, 3, 4) the RF current consumption can be
seen with different status of the control signals. The VCXO current is not
included in the results.
Table 2. Control Signals and Current Consumption
GSM,PCN
SYNTHPWR RXPWR TXPWR TXP Typical load
current / mA
Notes
L L L L 0.05 Leakage current
H L L L 42 Synthesizers active
H H L L 116 Reception
H L H L 94 TX active
H L H H 1400 Transmission (GSM)
H L H H 800 Transmission (PCN)